© RL Stephens Tool, 2003. All Rights Reserved.
|
|
Site Designed and Maintained by:
|
|
MACHINE TOOL PROBES
Tool Setting Probes for Machining Centers - NC1
|
|
1717 North Raymond Avenue • Anaheim, California 92801
|
|
Toll Free: 1 - 800 - 826 - 5133
|
|
Local Phone: 714 - 879 - 6637 • Fax: 714 - 879 - 0911
|
|
The NC1 is a laser based tool setting system designed for the
harshest machine tool environments. The system uses a laser source and CNC resident macros to set tool length and diameter and perform broken tool detection cycles. The NC1 can also be used to check for missing or broken inserts, verify the form of a tool and monitor a machine's thermal drift.
NC1 is available in fixed or separate configurations. Fixed
systems have the laser transmitter and receiver attached to a single mounting beam. Separate systems are supplied with discrete transmitter and receiver units and are designed to be mounted independently. |
|
NC1 fixed system kits
|
|
Includes:
|
|
NC1 fixed unit
NCi interface
Tool kit
Air regulator kit
Ø7 mm OD x 2 m conduit (2)
12.5 m cable
Ø15 mm OD x 4 m conduit
Adjuster pack
Tool setting software
Installation and training
|
|
NCI fixed system retrofit kits
Part number: NC1 - F150 - S
Part number: NC1 - F200 - S
Part number: NC1 - F300 - S
|
|
NC1 separate system kits
|
|
Includes:
|
|
NC1 separate unit
NCi interface
Tool kit
Air regulator kit
Ø7 mm OD x 2 m conduit (4)
12.5 m cable (2)
Ø15 mm OD x 4 m conduit (2)
Tool setting software
Installation and training
|
|
Note: When ordering a fixed system retrofit
kit, the customer must state which size NC1 (listed above) is required. |
|
NC1 separate system retrofit kits
|
|
Part number: NC1 - S700 - S
Part number: NC1 - S1000 - S
Part number: NC1 - S1400 - S
Part number: NC1 - S2000 - S
|
|
Repeatability
|
|
Separate system
|
|
Minimum tool
diameter
|
|
Breakage
|
|
Fixed system
|
|
Measurement
|
|
+, - 1.0 µm (0.00004 in)
|
|
+, - 2.0 µm (0.00008 in)
|
|
0.2 mm (0.008 in)
|
|
0.02 mm (0.0024 in)
|
|
Note: When ordering a fixed system retrofit kit, the
customer must select an NC1 based on its operating range. In addition, the customer must select tool setting software based on the control type. Brackets and an adjusting method are also needed for NC1 separate systems. These are not included with the NC1 separate systems and must be ordered additionally. Mounting brackets for various machines are continually developed. Bracket installation is NOT included with the standard separate system retrofit price, this service can be quoted upon request. |